F
1.3
Poor

1314 NELSON AVENUE, Bronx, NY, 10452

Bronx, NY 10452Built 20028 floors115 units
425 violations369 complaintsOwner: SENIOR LIVING OPTIONS, INC.

Tenant Reviews (0)

No reviews yet. Be the first to review this building!

Advertisement
Loading chart data...

Violations by Unit

(34 units)
UnitViolationsOpen
Common Areas
C:48B:66A:24
1440
Apt 8G
C:6B:25A:4
350
Apt 7I
C:6B:27A:1
340
Apt 6D
C:3B:12A:4
190
Apt 2S
C:6B:11A:2
190
Apt 6A
C:4B:13A:2
190
Apt 6Q
C:5B:13
180
Apt 5I
C:5B:6
110
Apt 3Q
C:1B:10
110
Apt 2R
C:2B:5A:4
110
Advertisement
Class B - HazardousVIOLATION OPEN

§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH

Apt: 6D

Feb 26, 2026
Class C - Immediately HazardousVIOLATION OPEN

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5I, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST

Apt: 5I

Feb 26, 2026
Class C - Immediately HazardousVIOLATION OPEN

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUILDING ENTRANCE DOOR GLASS PANE , 1st STORY

Feb 26, 2026
Class C - Immediately HazardousVIOLATION OPEN

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH

Apt: 6D

Feb 26, 2026
Class B - HazardousVIOLATION OPEN

§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH

Apt: 6D

Feb 26, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM

Feb 20, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 5th APARTMENT FROM SOUTH AT WEST

Apt: 2J

Feb 20, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 5th APARTMENT FROM SOUTH AT WEST

Apt: 2J

Feb 20, 2026
Class B - HazardousNOV SENT OUT

§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2S, 2nd STORY, 4th APARTMENT FROM WEST AT NORTH

Apt: 2S

Feb 19, 2026
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AT PUBLIC HALL, 5th STORY

Feb 19, 2026
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AT PUBLIC HALL, 6th STORY

Feb 19, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 6th STORY

Feb 19, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5I, 5th STORY, 4th APARTMENT FROM EAST AT SOUTH

Apt: 5I

Feb 19, 2026
Class A - Non-HazardousNOV SENT OUT

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 2nd STORY

Feb 19, 2026
Class A - Non-HazardousNOV SENT OUT

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 6th STORY

Feb 19, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2S, 2nd STORY, 4th APARTMENT FROM WEST AT NORTH

Apt: 2S

Feb 19, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STORY

Feb 19, 2026
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 2S, 2nd STORY, 4th APARTMENT FROM WEST AT NORTH

Apt: 2S

Feb 19, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 2S, 2nd STORY, 4th APARTMENT FROM WEST AT NORTH

Apt: 2S

Feb 19, 2026
Class A - Non-HazardousNOV SENT OUT

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 5th STORY

Feb 19, 2026

Building Details

Owner
SENIOR LIVING OPTIONS, INC.
View Portfolio →
Building Class
D1
Land Use
3
Residential Units
115
BBL
2025190001