D
2.3
Poor

2707 SEDGWICK AVENUE, Bronx, NY, 10468

Bronx, NY 10468Built 19246 floors78 units
192 violations176 complaintsOwner: KINGSBRIDGE GROUP LLC

Tenant Reviews (0)

No reviews yet. Be the first to review this building!

Advertisement
Loading chart data...

Violations by Unit

(14 units)
UnitViolationsOpen
Common Areas
C:13B:26A:14
530
Apt 1M
C:4B:25A:4
330
Apt 5M
C:3B:19A:1
230
Apt 2M
C:14B:3A:6
230
Apt 1P
C:6B:6A:3
150
Apt 5C
C:1B:9A:1
110
Apt 2K
C:3B:6A:1
100
Apt 4D
C:5B:2
70
Apt 4H
C:2B:3A:1
60
Apt 5H
C:3B:1
40
Advertisement
Class B - HazardousNOV SENT OUT

§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS AT PUBLIC HALL, 2nd STORY, SECTION ''NORTH''

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AN AIR CONDITIONER UNIT PROTRUDING MORE THAN 6 INCHES FROM WINDOWSILL, 4TH STORY BALCONY, 2ND FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT 1ST FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL

Jan 28, 2026
Class A - Non-HazardousNOV SENT OUT

§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WALL ERECTED WITH DRYWALL AND STUDS UNDER STAIRSCASE AT PUBLIC HALL, 1st STORY

Jan 28, 2026
Class A - Non-HazardousNOV SENT OUT

§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT 2ND FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF ELECTRICAL BIKE AT PUBLIC HALL, 1st STORY, SECTION ''SOUTH''

Jan 28, 2026
Class C - Immediately HazardousINVALID CERTIFICATION

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE (DEFECTIVE HINGES ON THE DOOR) AT THE BULKHEAD TO ROOF, AT PUBLIC HALL, 6th STORY, SECTION ''SOUTH''

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS INSTALL AT BUILDING ENTRANCE DOOR FROM STREET TO VESTIBULE (FIRE HAZARD) AT PUBLIC HALL, 1st STORY

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF CONSTRUCTION MATERALS, 3RD STORY BALCONY, 1ST FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL

Jan 28, 2026
Class C - Immediately HazardousVIOLATION DISMISSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE (DEFECTIVE HINGES ON THE DOOR) AT 2nd PUBLIC HALL BULKHEAD FROM NORTH

Jan 3, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER IN THE DOWN POSITION, AT 2ND FIRE ESCAPE FROM SOUTH AT EAST BUILDING FRONT AT FIRE ESCAPE, 2nd STORY

Jan 3, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER IN THE DROP POSITION AT 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL AT FIRE ESCAPE, 2nd STORY

Jan 3, 2026
Class B - HazardousINVALID CERTIFICATION

§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF ELECTRICAL BIKE CHAINED TO RAILING AT PUBLIC HALL, 5th STORY

Jan 3, 2026
Class A - Non-HazardousNOV SENT OUT

§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING SHOE, PROPERLY SECURE WITH APPROPRIATE NUTS AND BOLTS AT 3RD FIRE ESCAPE FROM SOUTH AT EAST BUILDING FRONT AT FIRE ESCAPE, 2nd STORY

Jan 3, 2026
Class B - HazardousVIOLATION DISMISSED

§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT EAST WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 1P, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH''

Apt: 1P

Oct 24, 2025
Class B - HazardousVIOLATION DISMISSED

§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL AT 1ST CLOSET FROM EAST AT SOUTH IN THE PRIVATE HALLWAY LOCATED AT APT 1P, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH''

Apt: 1P

Oct 24, 2025
Class C - Immediately HazardousVIOLATION DISMISSED

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1P, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH''

Apt: 1P

Oct 24, 2025
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 2nd STORY

Oct 24, 2025
Class B - HazardousVIOLATION DISMISSED

§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING AT PUBLIC HALL, 2nd STORY

Oct 24, 2025

Building Details

Owner
KINGSBRIDGE GROUP LLC
View Portfolio →
Building Class
C7
Land Use
4
Residential Units
69
BBL
2032530001