1102 AVENUE K, Brooklyn, NY, 11230
No reviews yet. Be the first to review this building!
Violations by Unit
(5 units)§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UPPER LEVEL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3BB, 3rd STORY, APARTMENT AT NORTH
Apt: 3BB
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE AT DOOR TO BASEMENT AT SOUTH YARD
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHEAST
Apt: 3G
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHEAST
Apt: 3G
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL AT THE NORTH WALL LEADING TO UPPER FLOOR IN THE 1st PRIVATE HALLWAY LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHEAST
Apt: 3G
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHEAST
Apt: 3G
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHEAST
Apt: 3G
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHEAST
Apt: 3G
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR TO,ROOM WITH FIRE ESCAPE IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE 1st BATHROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUSION BEYOND WINDOW SILL AT, BALCONY, NORTHWEST SECTION , 3RD STORY, WEST YARD, AT FIRE ESCAPE
§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES FROM ELECTRICAL OUTLET AT NORTH WALL TO CEILING LIGHT FIXTURE IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT GLOBE COVER AT CEILING LIGHT FIXTURE IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd BATHROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st BATHROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE WEST WALL AT 4TH STORIES , NORTHEAST SECTION, AT PUBLIC HALL STAIRS
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd BATHROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED AND MISSING CERAMIC FLOOR TILES IN THE 3rd BATHROOM FROM NORTH AT WEST LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTHEAST''
Apt: 3G